Continuous Flow Grain Dryers

Site updated: 10 November, 2023

Revision: 10.3

Kentra Grain Systems Limited, Anonna House, Clay Pit Lane, Roeclife, Boroughbridge Tel: (01423) 326665 Fax:  webmaster@kentra.co.uk Technical Specifications

DRYER

MODEL

NO OF

FANS

RATED

THROUGHPUT

(tonnes per hour)

INSTALLED

POWER

REQUIREMENT

(kW)

OVERALL

HEIGHT

(metres)



(see Note 1)

(see Note 2)

(see Note 3)

720

1 x 7.5kW

6.3

8.81

5.825

920

1 x 7.5kW

8.3

8.81

6.335

1120

1 x 7.5kW

10.4

8.81

6.885

1320

1 x 11kW

12.5

12.31

7.945

1520

1 x 11kW

14.6

12.31

8.475


825

1 x 7.5kW

8.0

8.81

6.090

1125

1 x 7.5kW

10.5

8.81

6.620

1325

1 x 11kW

13.0

12.31

7.150

1625

1 x 11kW

16.0

16.31

8.210

1925

2 x 7.5kW

18.5

16.31

8.740

2225

2 x 7.5kW

21.5

16.31

9.800


1340

2 x 7.5kW

12.6

16.86

5.825

1740

2 x 7.5kW

16.6

16.86

6.335

2140

2 x 7.5kW

20.8

17.62

6.885

2540

2 x 11kW

25.0

25.70

7.945

3040

2 x 11kW

29.2

25.70

8.475

3440

4 x 7.5kW

33.4

33.70

9.535


1650

2 x 7.5kW

16.0

16.86

6.335

2150

2 x 7.5kW

21.0

17.62

6.620

2650

2 x 11kW

26.0

25.70

7.150

3250

2 x 11kW

32.0

25.70

8.210

3750

4 x 7.5kW

37.0

33.70

8.740

4350

4 x 7.5kW

42.0

33.70

9.800

4750

4 x 11kW

47.0

47.70

10.330


Note 1:





Dryer throughputs are based on cleaned barley (density 700kg/m³) drying from 20-15% MCwb at 125° Celsius with an ambient temperature of 15° Celsius and 80% RH. Variations in operating conditions and the product being dried may affect throughputs by up to 10% either way.

Note 2:





Installed power requirements are based on three phase electrical supply. Please contact our office for technical information concerning single phase electrical supplies.

Note 3:





Dryer overall height includes 420mm clearance under discharge hopper outlet.